Description
EGLK THERMOSIPHON SOLAR WATER HEATERS
EGLK thermosiphon systems heat water using the sun and natural circulation—no pump required. As solar energy warms the flat-plate collectors, hot fluid rises into the tank while cooler fluid returns to the collectors, delivering reliable hot water with very low running cost. Tanks are double-enameled steel with 50 mm high-density PU insulation, magnesium anode, and an ENERGON® diffuser that improves stratification for higher draw-off efficiency. Each system includes an electric immersion back-up (1.5–4 kW) with a safety thermostat for cloudy periods or peak use. Standard flat-roof frames are supplied at 26° tilt (universal bases also available for 0°/26°/45°), suitable for sunny climates; use antifreeze where freezing is possible. Typical applications include homes, villas, and small businesses. Two sizes are available: 200 L or 300 L tanks paired with titanium-selective collectors (total 4.00 m²), Solar Keymark certified to EN 12975/12976.
What’s Included / Not Included
EGLK 200/4.00 & EGLK 300/4.00 — Included
- Storage tank: double-enameled steel with ENERGON® diffuser, magnesium anode, 50 mm PU insulation.
- Collectors: 2 × EPI 25NV (total 4.00 m²).
- Mounting frame: galvanized steel, flat-roof configuration (26° typical); universal bases also available (0°/26°/45°).
- Electric back-up heater (1.5–4 kW) with safety thermostat.
- Basic fasteners & installation manual. [SPECIFY]
Not Included (to be specified by installer)
- T&P relief valve: M ½″.
- Solar expansion vessel: 8 L / 10 bar (size/charge to match system volume/pressure).
- Isolation valves, non-return/check valves, air vent, drain cocks, thermostatic mixing valve, dielectric unions.
- Electrical cabling, isolator, breaker, conduit and glands to local code.
- Glycol/heat-transfer fluid (for closed-loop), substrate-specific roof anchors.
Technical Specifications (comparison table)
| Parameter | EGLK 200/4.00 | EGLK 300/4.00 |
|---|---|---|
| System type | Closed-loop thermosiphon; mantel-type heat exchanger | Closed-loop thermosiphon; mantel-type heat exchanger |
| Tank capacity & material | 200 L nominal; double-enameled steel (real ≈ 189 L) | 300 L nominal; double-enameled steel (real ≈ 295 L) |
| Insulation | PU, 50 mm (≈ 52 kg/m³) | PU, 50 mm (≈ 52 kg/m³) |
| Anode | Magnesium rod | Magnesium rod |
| Ports | DHW M ½″; closed loop M ¾″ | DHW M ½″; closed loop M ¾″ |
| Max operating pressure & relief | 150 PSI | 150 PSI |
| Collectors & area | 2 × EPI 25NV; 4.00 m² total | 2 × EPI 25NV; 4.00 m² total |
| Collector dimensions (each) | 1000 × 2000 × 85 mm | 1000 × 2000 × 85 mm |
| Absorber & glazing | Titanium-selective (α ≥ 0.95, ε ≤ 0.05); 3.2 mm low-iron safety glass (τ ≥ 0.90) | Same |
| Mount type & tilt | Flat-roof frame, 26° (universal 0°/26°/45° available) | Same |
| Overall tank size (Ø × length) | 580 × 1320 mm | 580 × 1820 mm |
| System empty weight | ≈ 170.20 kg | ≈ 190.50 kg |
| Back-up heater rating & voltage | 1.5–4 kW; voltage 220-240V | 1.5–4 kW; voltage 220-240V |
| Electrical protection/IP | IPX4 | IPX4] |
| Recommended expansion vessel & pre-charge | 8 L / 10 bar; pre-charge [SPECIFY] | 8 L / 10 bar; pre-charge [SPECIFY] |
| Pipe sizes | Closed-loop hose Ø 22 mm | Same |
| Warranty (see §11) | Tank 1 yrs; Collectors 1yrs; Mounting 1 yr; Electrical 1 yr | Same (per customer policy) |
Notes: Height “Z” in catalogue tables is referenced at 45° frames; installed 26° height is lower.











Reviews